Acta Metallurgica Sinica (English Letters) ›› 1992, Vol. 5 ›› Issue (8): 104-109.

• Research paper • Previous Articles     Next Articles

MIXED MODE SCC OF 18-8 STAINLESS STEEL IN BOILING 42% MgCl_2 SOLUTION

GAO Hua CAO Weijie ZHOU Deqi WANG Ruizhen Shanghai University of Engineering Science,Shanghai,China   

  • Received:1992-08-11 Revised:1992-08-11 Online:1992-08-11 Published:2009-10-10

Abstract: A series of mixed mode tests were carried out on 18-8 stainless steel in boiling 42% MgCl_2 solution.The results show that for any K_Ⅱ/K_Ⅰ ratio,the SCC direction coin- cides well with the crack tip maximum normal stress plane,while the SCC resistance of the material reduces as the ratio of K_Ⅱ/K_Ⅰ increases.The experimental results were discussed in the light of anode dissolving mechanism and the effect of mixed mode loading on crack tip stress and strain.It is concluded that for fracture analysis if mixed mode cracks were simply taken into account as mode Ⅰ cracks,and only mode Ⅰ testing results as mode Ⅰ fracture criter- ion were employed,it may not be safe.

Key words: 18-8 stainless steel, stress corrosion, mixed mode